Datalogger restart
| Parameter | Description | Required |
|---|---|---|
| action | restartCollector | True |
| pn | Datalogger number | True |
response:
| Parameter | Description | Required |
|---|---|---|
| ret | The restart results and possible values are shown in the table below | True |
| Restart result | Description |
|---|---|
| 0x00 | Successfully restarted, the command has been issued to the Datalogger, and the Datalogger has a clear response indicating that it will restart |
| 0x01 | The instruction has been issued to the Datalogger |
| 0x02 | Command issuance failed, Datalogger may be offline |
{
"err":0,
"desc":"ERR_NONE",
"dat":{
"ret":0
}
}
Possible errors:
| Response error code | Description | Details |
|---|---|---|
| 0x0006 | ERR_FORMAT_ERROR | Parameter error |
| 0x0101 | ERR_NOT_FOUND_COLLECTOR | Unable to find Datalogger |