Query the power generation of Inverters or other power generation Device on a certain day

for example: http://api.shinemonitor.com/public/?sign=45a0317337cad1b975b7cc8e6ae35401daa5c356&salt=6799118618252297881&token=5b13e18eaa179d4bdce4cf2cc0e66eaa506c7f27ccac6b9e7beaa190ec0e386f&action=queryDeviceEnergyDay&pn=COLLECTOR0001&devcode=752&devaddr=1&sn=687484400018&date=2017-04-05&source=0&_app_client_=android&_app_id_=com.demo.test&_app_version_=3.6.2.1

Parameter Description Required
action queryDeviceEnergyDay True
pn Datalogger number True
devcode Device protocol encoding True
devaddr Device address (485 bus) True
sn Device serial number True
date Date to query, format: yyyy-mm-dd, Date is considered as the time zone where the Device is located, If this parameter is not passed, it will be defaulted to today False

response:

Parameter Description Required
energy Power generation, Standardized units True
{
    "err":0,
    "desc":"ERR_NONE",
    "dat":{
        "energy":"10.0001"
    }
}

Possible errors:

Response error code Description Details
0x0006 ERR_FORMAT_ERROR Parameter error
0x000C ERR_NO_RECORD No records (no data reported by the Device was found)
0x0102 ERR_NOT_FOUND_DEVICE Device not found
Copyright © eybond 2022 all right reserved,powered by Gitbook文档更新时间: 2023-07-18 13:50:20

results matching ""