Query the rated power and model of Inverters or other power generation Device

for example: http://api.shinemonitor.com/public/?sign=45a0317337cad1b975b7cc8e6ae35401daa5c356&salt=6799118618252297881&token=5b13e18eaa179d4bdce4cf2cc0e66eaa506c7f27ccac6b9e7beaa190ec0e386f&action=queryDeviceRateActiveOutputPower&pn=COLLECTOR0001&devcode=752&devaddr=1&sn=687484400018&source=0&_app_client_=android&_app_id_=com.demo.test&_app_version_=3.6.2.1

Parameter Description Required
action queryDeviceRateActiveOutputPower True
pn Datalogger number True
devcode Device protocol encoding True
devaddr Device (485 bus) True
sn Device serial number True

response:

Parameter Description Required
ratePower Rated power, Standardized units True
devtype Model, defined by Device manufacturer False
{
    "err":0,
    "desc":"ERR_NONE",
    "dat":{
        "ratePower":"50000.0000",
        "devtype": "SK50K"
    }
}

Possible errors:

Response error code Description Details
0x0006 ERR_FORMAT_ERROR Parameter error
0x000C ERR_NO_RECORD No record (no Device rating information found)
0x0102 ERR_NOT_FOUND_DEVICE Device not found
Copyright © eybond 2022 all right reserved,powered by Gitbook文档更新时间: 2023-07-18 13:48:57